Reliance Water Heaters N71120NE Manuale Utente

Pagina di 56
32
c.   A  sulfate  reducing  bacteria  which  has  accumulated 
within  the  water  heater  (this  harmless  bacteria  is 
nontoxic to humans).
d.   An excess of active hydrogen in the tank. This is caused 
by the corrosion protective action of the anode.
Smelly water may be eliminated or reduced in some water heater 
models by replacing the anode(s) with one of less active material, 
and then chlorinating the water heater tank and all water lines.
Contact  the  local  water  heater  supplier  or  service  agency  for 
further  information  concerning  an Anode  replacement  Kit  and 
this chlorination treatment.
If smelly water persists after anode replacement and chlorination 
treatment, we can only suggest that chlorination or aeration of the 
water supply be considered to eliminate the water problem.
Do not remove the anode leaving the tank unprotected. By doing 
so, all warranty on the water heater tank is voided.
“air” in hot water faucets
HYDrogeN gAS: Hydrogen gas can be produced in a hot water 
system that has not been used for a long period of time (generally 
two weeks or more). Hydrogen gas is extremely flammable and 
explosive. To prevent the possibility of injury under these conditions, 
we  recommend  the  hot  water  faucet,  located  farthest  away,  be 
opened  for  several  minutes  before  any  electrical  appliances 
which are connected to the hot water system are used (such as 
a dishwasher or washing machine). If hydrogen gas is present, 
there will probably be an unusual sound similar to air escaping 
through the pipe as the hot water faucet is opened. There must be 
no smoking or open flame near the faucet at the time it is open.
high water temperature shut off system
This water heater is equipped with an automatic reset type high limit 
(energy  Cutoff)  sensor. The  high  limit  switch  interrupts  the  main 
burner gas flow should water temperature reach 195°f (91°C).
The high limit will automatically reset when the water temperature 
drops below 140°f (60°C). After cooling the tank temperature, 
turn  off  the  electric  power  to  the  water  heater  for  at  least  10 
seconds by using the switch on the front of the control box. Turn 
on the water heater. If this fails to correct the problem, contact 
your plumber or service representative.
start up conditions
smoke/odor
It is not uncommon to experience a small amount of smoke and 
odor during the initial start-up. This is due to burning off of oil 
from metal parts, and will disappear in a short while.
strange sounds
Possible noises due to expansion and contraction of some metal 
parts during periods of heat-up and cool-down do not necessarily 
represent harmful or dangerous conditions.
Condensation causes sizzling and popping within the burner area 
during  heating  and  cooling  periods  and  should  be  considered 
normal. See “Condensation" section in this manual.
condensation
Whenever  the  water  heater  is  filled  with  cold  water,  some 
condensate will form while the burner is on.  A water heater may 
appear to be leaking when in fact the water is condensation.  This 
usually happens when:
a.  A new water heater is filled with cold water for the first time.
b.  Burning gas produces water vapor in water heaters, particularly 
high efficiency models where flue temperatures are lower.
c.  Large amounts of hot water are used in a short time and the 
refill water in the tank is very cold.
moisture from the products of combustion condense on the cooler 
tank surfaces and form drops of water which may fall onto the burner 
or other hot surfaces to produce a “sizzling” or “frying” noise.
operational conditions
smelly water
In each water heater there is installed at least one anode rod for
corrosion  protection  of  the  tank.  Certain  water  conditions  will 
cause  a  reaction  between  this  rod  and  the  water.  The  most 
common  complaint  associated  with  the  anode  rod  is  one  of  a 
“rotten egg smell” in the hot water. The smell is a result of four 
factors which must all be present for the odor to develop:
a.   A concentration of sulfate in the supply water.
b.   Little or no dissolved oxygen in the water.
for your information
serVice
The installer may be able to observe and correct certain problems 
which may arise when the unit is put into operation.  HoWeVer, 
it  is  recommended  that  only  qualified  service  agents,  using 
appropriate test equipment, be allowed to service the heater.
As  preliminary  step,  check  wiring  against  diagram,  check  for 
grounded, broken or loose wires.  Check all wire ends to be sure 
that they are making good contact.
electrical serVicing
LABeL ALL WIreS PrIor To DISCoNNeCTIoN WHeN SerVICINg  
CoNTroLS.  WIrINg  errorS  CAN  CAuSe  ImProPer  AND 
DANgerouS oPerATIoN.
VerIfY ProPer oPerATIoN AfTer  SerVICINg.