GENERAL DATA 
 
2-23 
 
2.2.13.  WALL TYPE (RAK-18PEA/25PEA/35PEA/50PEA) 
INDOOR 
Unit 
RAK-18PEA 
RAK-25PEA 
RAK-35PEA 
RAK-50PEA 
Nominal capacity adjustable  
  
Nominal Cooling capacity (min - max) 
kW 
2.00 (0.90 - 2.50)  2.50 (0.90 - 3.10)  3.50 (0.90- 4.00) 
5.00 (1.90- 5.20) 
Cooling sensible capacity  
kW 
1.9 
2.1 
3.2 
3.4 
Nominal Heating capacity (min - max) 
kW 
2.50 (0.90 - 3.20)  3.40 (0.90- 4.40) 
4.20 (0.90- 5.00) 
6.00 (2.2- 7.30) 
Noise level cooling (sound pressure) 
(SL / L / M / H) 
dB(A) 
21/27/33/37 
22/24/33/40 
25/26/36/43 
28/30/40/46 
Noise level heating (sound pressure) 
(SL / L / M / H) 
dB(A) 
19/28/34/38 
20/21/34/41 
26/27/36/44 
25/30/39/47 
Noise level (sound power) 
dB(A) 
51 
54 
57 
60 
Air flow cooling mode (SL / L / M / H) 
m
3
/h 
312/350/ 400/440  333/370/430/510  333/400/485/600 
333/450/600/700 
Air flow heating mode (SL / L / M / H)  
m
3
/h 
312/350/420/480  333/400/500/570  333/520/550/660 
433/510/650/770 
Fan Motor 
25 
25 
25 
25 
Drain pump pressure lift 
cm 
Static pressure (SL / L / M / H) (nominal 
conditions SP 00) 
Pa 
Dehumidification 
l/h 
1.2 
1.4 
1.6 
2.0 
Included drain pump 
 
Max. height available for drain pump 
(RAD/RAI only) 
 
Dimensions (H x W x D) 
mm 
280x780x218 
280x780x218 
280x780x218 
280x780x218 
Panel dimensions (H x W x D) 
mm 
Weight 
kg 
7.5 
7.5 
7.5 
7.5 
Colour (Munsell Code) 
 
White 
Condensate Drain 
mm 
φ16
 
φ16
 
φ16
 
φ16
 
Panel weight 
kg 
Panel reference 
 
Color of the panel (RAL) 
 
Running current 
2.97/3.00 
3.58/4.25 
5.00/5.03 
6.85/7.29 
Power supply 
 
35 V DC from 
outdoor unit 
35 V DC from 
outdoor unit 
35 V DC from 
outdoor unit 
35 V DC from 
outdoor unit 
Cable section 
mm² 
0.75x2 
0.75x2 
0.75x2 
0.75x2 
Piping diameter (Liq / Gas) 
  
1/4” - 3/8” 
1/4” - 3/8” 
1/4” - 3/8” 
1/4” - 1/2” 
Drain diameter (ext) 
mm 
φ16 
φ16 
φ16 
φ16 
Remote control (standard/optional)  * 
 
RAR-5F1/  
SPX-RCDB 
RAR-5F1/  
SPX-RCDB
 
RAR-5F1/  
SPX-RCDB
 
RAR-5F1/ 
SPX-RCDB
 
Filter 
 
 
 
 
 
ACL Filter (optional)  
 
Wasabi 
Wasabi 
Wasabi 
Wasabi 
Dimensions (H x W x D) 
mm 
48x243x5
 
48x243x5
 
48x243x5
 
48x243x5
 
Pre-filter (Standard / Optional) 
 
Washable / 
Stainless 
Washable / 
Stainless 
Washable / 
Stainless 
Washable / 
Stainless 
*
more information regarding remote control can be found in Chapter 9
*
 
 
NOTE: 
1.  The nominal cooling and heating capacity is the 
combined capacity of the HITACHI standard split 
system, and are based on the ISO 5151.
 
 
2.  The Sound Pressure Level is based on the following 
conditions:  
1.5  meter beneath the Unit 
The above data was measured in an anechoic 
chamber. Please take into consideration reflected 
sound of your specific site 
 
Operation Conditions 
Cooling 
Heating 
 
Indoor Air Inlet Temperature
 
dB 
27.0 °C
 
20.0 °C 
 
WB 
19.0 °C
 
 
 
Outdoor Air Inlet 
Temperature
 
dB 
35.0 °C
 
7.0 °C
 
 
WB 
 
6.0 °C 
 
Piping Length: 5.0 meters; Piping Lift: 0 meter 
dB: Dry Bulb; WB: Wet Bulb