Hitachi RAF-35RPA RAF35RPA 사용자 설명서
제품 코드
RAF35RPA
GENERAL DATA
2-23
2.2.13. WALL TYPE (RAK-18PEA/25PEA/35PEA/50PEA)
INDOOR
Unit
RAK-18PEA
RAK-25PEA
RAK-35PEA
RAK-50PEA
Nominal capacity adjustable
-
-
-
-
Nominal Cooling capacity (min - max)
kW
2.00 (0.90 - 2.50) 2.50 (0.90 - 3.10) 3.50 (0.90- 4.00)
5.00 (1.90- 5.20)
Cooling sensible capacity
kW
1.9
2.1
3.2
3.4
Nominal Heating capacity (min - max)
kW
2.50 (0.90 - 3.20) 3.40 (0.90- 4.40)
4.20 (0.90- 5.00)
6.00 (2.2- 7.30)
Noise level cooling (sound pressure)
(SL / L / M / H)
(SL / L / M / H)
dB(A)
21/27/33/37
22/24/33/40
25/26/36/43
28/30/40/46
Noise level heating (sound pressure)
(SL / L / M / H)
(SL / L / M / H)
dB(A)
19/28/34/38
20/21/34/41
26/27/36/44
25/30/39/47
Noise level (sound power)
dB(A)
51
54
57
60
Air flow cooling mode (SL / L / M / H)
m
3
/h
312/350/ 400/440 333/370/430/510 333/400/485/600
333/450/600/700
Air flow heating mode (SL / L / M / H)
m
3
/h
312/350/420/480 333/400/500/570 333/520/550/660
433/510/650/770
Fan Motor
W
25
25
25
25
Drain pump pressure lift
cm
-
-
-
-
Static pressure (SL / L / M / H) (nominal
conditions SP 00)
conditions SP 00)
Pa
-
-
-
-
Dehumidification
l/h
1.2
1.4
1.6
2.0
Included drain pump
-
-
-
-
Max. height available for drain pump
(RAD/RAI only)
(RAD/RAI only)
-
-
-
-
Dimensions (H x W x D)
mm
280x780x218
280x780x218
280x780x218
280x780x218
Panel dimensions (H x W x D)
mm
-
-
-
-
Weight
kg
7.5
7.5
7.5
7.5
Colour (Munsell Code)
White
Condensate Drain
mm
φ16
φ16
φ16
φ16
Panel weight
kg
-
-
-
-
Panel reference
-
-
-
-
Color of the panel (RAL)
-
-
-
-
Running current
A
2.97/3.00
3.58/4.25
5.00/5.03
6.85/7.29
Power supply
35 V DC from
outdoor unit
35 V DC from
outdoor unit
35 V DC from
outdoor unit
35 V DC from
outdoor unit
Cable section
mm²
0.75x2
0.75x2
0.75x2
0.75x2
Piping diameter (Liq / Gas)
1/4” - 3/8”
1/4” - 3/8”
1/4” - 3/8”
1/4” - 1/2”
Drain diameter (ext)
mm
φ16
φ16
φ16
φ16
Remote control (standard/optional) *
RAR-5F1/
SPX-RCDB
RAR-5F1/
SPX-RCDB
RAR-5F1/
SPX-RCDB
RAR-5F1/
SPX-RCDB
Filter
ACL Filter (optional)
Wasabi
Wasabi
Wasabi
Wasabi
Dimensions (H x W x D)
mm
48x243x5
48x243x5
48x243x5
48x243x5
Pre-filter (Standard / Optional)
Washable /
Stainless
Washable /
Stainless
Washable /
Stainless
Washable /
Stainless
*
more information regarding remote control can be found in Chapter 9
*
NOTE:
1. The nominal cooling and heating capacity is the
combined capacity of the HITACHI standard split
system, and are based on the ISO 5151.
system, and are based on the ISO 5151.
2. The Sound Pressure Level is based on the following
conditions:
-
1.5 meter beneath the Unit
The above data was measured in an anechoic
chamber. Please take into consideration reflected
sound of your specific site
chamber. Please take into consideration reflected
sound of your specific site
Operation Conditions
Cooling
Heating
Indoor Air Inlet Temperature
dB
27.0 °C
20.0 °C
WB
19.0 °C
Outdoor Air Inlet
Temperature
Temperature
dB
35.0 °C
7.0 °C
WB
6.0 °C
Piping Length: 5.0 meters; Piping Lift: 0 meter
dB: Dry Bulb; WB: Wet Bulb
dB: Dry Bulb; WB: Wet Bulb