Steca Solar charge controller 12 V, 24 V 30 A Steca PR 3030 104517 Manuale Utente

Codici prodotto
104517
Pagina di 16
10
708.19 | 08.44
6.3. Gel / Liquid Battery Type Setting
The standard setting is “Li”. 
The setting of the battery type 
influences the cutoff voltage of 
the controller. If you use a Gel 
or AGM battery, you have to 
change the battery type to GEL.
Caution! An incorrect battery type setting can damage the battery!
6.4. Night Light Function Setting
This setting provides three options in the following order:
OFF: The function is deactivated (default).
Operating time-choice of 1 to 8 hours.
ON: The consumer output remains on for the entire night. 
This function controls the load output only when it is dark (at night). During 
daylight the consumer output remains off. The connected solar module 
records information on the light intensity.
The load is activated once the solar module detects that it is dark.  
Once it becomes light, the regulator deactivates the consumer output 
regardless which illumination duration has been selected. Due to different 
properties of various modules, the twilight threshold cannot be specified 
accurately. An activation delay cannot be set when twilight sets in.
6.5. Default Setting (Presetting) Activation
Calling up the default settings (PRE) deletes the 
previous settings and resets the charge controller to 
the factory settings.
The default setting is: SOC Control / Gel Storage 
Battery / Night Light OFF
6.6. Auto-test
The auto-test can determine whether the charge 
controller is fully operational and localize all possible 
windows simultaneously. 
The following preparations must be met before you 
can start the text using the menu item. Non-compli-
ance can lead to incorrect test results.
A)  Disconnect the solar module from the charge regulator   
 
(both connections). The battery must be connected.
B)  Connect a small functional DC consumer, e.g. an  
 
energy-saving lamp, to the load output.
C)  Press the right button to manually disconnect the load.  
 
The load symbol no longer appears in the display.
After these preparations, call up the auto-test menu item and continue as 
follows:
D)  Press the right button. The display begins to flash.