Steca Solar charge controller 12 V, 24 V 30 A Steca PR 3030 104517 Manuale Utente
Codici prodotto
104517
9
708.19 | 08.44
Using this SOC information, you always have an accurate overview on the
actual battery level. Using the SOC, the regulator also controls the selection
of the charging procedure and the deep discharging protection in order to
ideally maintain the battery. If one of the parameters cannot be recorded
because for example, a consumer or charging source is directly connected to
the battery, the SOC calculation is invalid. The regulator can then be set to
the more simplified voltage-guided control, see chapter 6..
The SOC calculation is restarted each time the regulator is reinstalled.
The SOC calculation is restarted each time the regulator is reinstalled.
5.2. PWM Charge Control
The regulator applies a constant voltage charging to the battery. The entire
available electricity provided by the charging source is used for charging the
battery until the final voltage is reached. A pulse width modulator (PWM)
regulates the charging current by briefly closing the module input (shunt
charge controller) in the charge control area.
Depending on the actual battery level, various charging procedures, float
Depending on the actual battery level, various charging procedures, float
charging, boost charging and equalization charging are automatically
performed. In doing so, the settings for the battery and control type are
factored in. The final charging voltage is temperature compensated. Every
30 days a test is automatically performed to determine if an equalization
charging must be carried out.
5.3. Deep Discharging Protection
The regulator protects the connected battery against an excessive
discharging. If the battery falls below a specified charge level (during SOC
control) or battery voltage (during the voltage-controlled function), the load
output is disconnected and the discharge of the battery is prevented. The
display shows the early warning and disconnection during deep discharging.
The setpoints of the deep discharging protection are predefined and cannot
be reset.
6. Regulator Settings
The battery type, control type and night light function can be set in the
regulator. Points for the auto-test and the serial number query are also loca-
ted within the menu. The settings remain when the battery is disconnected.
6.1. Calling up and Modifying the Settings
Press the left button for at least 3 seconds to open the first setting window
(control type). Press the left button again to call up the various windows.
Press the right button to modify settings. The display begins to flash. Now,
Press the right button to modify settings. The display begins to flash. Now,
with the left button select the settings options. The setting must be saved
with the right button. The display then stops flashing.
The normal window reappears after a 30 second waiting period or pressing
The normal window reappears after a 30 second waiting period or pressing
the left button for 3 seconds. This applies to all windows.
6.2. SOC Setting / Voltage Control
The SOC control is the factory setting. This way, the charging procedure and
the deep discharging protection are controlled by the calculated SOC value
for ideal battery usage.
Only fixed voltage thresholds
are used and the SOC bar dis-
play is faded out in all windows
during voltage-guided control
(UoL).