Steca Solar charge controller 12 V, 24 V 30 A Steca PR 3030 104517 Manuale Utente

Codici prodotto
104517
Pagina di 16
9
708.19 | 08.44
Using this SOC information, you always have an accurate overview on the 
actual battery level. Using the SOC, the regulator also controls the selection 
of the charging procedure and the deep discharging protection in order to 
ideally maintain the battery. If one of the parameters cannot be recorded 
because for example, a consumer or charging source is directly connected to 
the battery, the SOC calculation is invalid. The regulator can then be set to 
the more simplified voltage-guided control, see chapter 6.. 
The SOC calculation is restarted each time the regulator is reinstalled.
5.2. PWM Charge Control
The regulator applies a constant voltage charging to the battery. The entire 
available electricity provided by the charging source is used for charging the 
battery until the final voltage is reached. A pulse width modulator (PWM) 
regulates the charging current by briefly closing the module input (shunt 
charge controller) in the charge control area.
Depending on the actual battery level, various charging procedures, float 
charging, boost charging and equalization charging are automatically 
performed. In doing so, the settings for the battery and control type are 
factored in. The final charging voltage is temperature compensated. Every 
30 days a test is automatically performed to determine if an equalization 
charging must be carried out.
5.3. Deep Discharging Protection
The regulator protects the connected battery against an excessive 
discharging. If the battery falls below a specified charge level (during SOC 
control) or battery voltage (during the voltage-controlled function), the load 
output is disconnected and the discharge of the battery is prevented. The 
display shows the early warning and disconnection during deep discharging. 
The setpoints of the deep discharging protection are predefined and cannot 
be reset.  
6.  Regulator Settings
The battery type, control type and night light function can be set in the 
regulator. Points for the auto-test and the serial number query are also loca-
ted within the menu. The settings remain when the battery is disconnected.  
6.1. Calling up and Modifying the Settings
Press the left button for at least 3 seconds to open the first setting window 
(control type). Press the left button again to call up the various windows.
Press the right button to modify settings. The display begins to flash. Now, 
with the left button select the settings options. The setting must be saved 
with the right button. The display then stops flashing.
The normal window reappears after a 30 second waiting period or pressing 
the left button for 3 seconds. This applies to all windows.
6.2. SOC Setting / Voltage Control
The SOC control is the factory setting. This way, the charging procedure and 
the deep discharging protection are controlled by the calculated SOC value 
for ideal battery usage. 
Only fixed voltage thresholds 
are used and the SOC bar dis-
play is faded out in all windows 
during voltage-guided control 
(UoL).