 Description of Functions
The charge controller protects the battery from being overcharged by the solar array and from 
being deep discharged by the loads. The charging characteristics include several stages which 
include automatic adaptation to the ambient temperature.
The charge controller adjusts itself automatically to 12V or 24V system voltage.
The charge controller has a number of safety and display functions.
 Connecting and Grounding
The controller is intended for indoor use only. Protect it from direct sunlight and place it in a dry 
environment. Never install it in humid rooms (like bathrooms). The controller measures the ambient  
temperature to determine the charging voltage. Controller and battery must be installed in the same  
room.  The   controller   warms   up   during   operation,   and   should   therefore   be   installed   on   a   non  
flammable surface only.
Connect the controller by following the steps described below to avoid installation faults.
Observe the following connection sequence when installing the system:
1. Connect the battery to the charge controller – plus and minus.
         2. Connect the photovoltaic modules to the charge controller – plus and minus.
         3. Connect the load to the charge controller – plus and minus.
         Follow the reverse procedure when uninstalling!
To avoid any voltage on the wires, first connect the wire to the controller, then to the battery,  
photovoltaic modules. But for load,  first connect the wire to the load, then to the controller.
Recommended minimum wire size: 10 mm
2
;
Make sure the wire length between battery and controller is as short as possible.