Insys GPRS 5.0 serial 11-02-01-03-10.014 Manuale Utente

Codici prodotto
11-02-01-03-10.014
Pagina di 82
Connection 
 
INSYS GPRS 5.0 serial 
 
36
 
 
Mai 06
 
5.3.3  Termination 
Connections can be terminated as follows: 
Manual termination using the ATH command in online command 
mode 
By DTR drop (for the setting AT&D2
If the remote terminal hangs up 
After switching from data mode to online mode, the connection 
will remain established. However, data is no longer transmitted to 
the remote terminal. The online command mode is also entered 
through DTR drop (setting AT&D1) or by activating the reset input 
twice within 10 seconds. 
Hang up (terminate connection to the other party) 
The connection was terminated. 
5.3.4  Connection to analogue modems 
 
Alternatively, the settings can be entered or modified using the 
terminal program. 
To call an analogue modem, an analogue protocol must be set. 
E.g.: The protocol V.32 with a data rate of 9600 baud. 
5.3.5  Connection to ISDN TAs 
 
Alternatively, the settings can be entered or modified using the 
terminal program. 
To call an ISDN TA it is necessary to set the ISDN protocol V.110. 
While doing so it must be observed that the remote terminal has to 
work with the same protocol as well. 
E.g.: The protocol V.110 with a data rate of 9600 baud. 
ATH 
<1 sec. pause> 
+++ 
<1 sec. pause> 
OK 
AT+CBST=<n> 
AT+CBST=7 
AT+CBST=<n> 
AT+CBST=71