3.1.2  Actual Values 
A LOGO! control program is divided into blocks. Actual values are assigned to each 
of these blocks during runtime of the control program. For example, for pulse 
counters, the actual value is the pulse count. 
 
While the PA buffer displays the permanent LOGO! I/O elements (inputs, outputs, 
etc.), an actual value scan can be used to read out function block values of the 
LOGO! control program itself. 
 
Actual values of function blocks are scanned via SMS. The utilized blocks are 
addressed using three-digit block numbers that are assigned by the LOGO!Soft 
Comfort PC software. 
 
The following function blocks are supported by the INSYS GSM 4.2 LOGO!: 
 
-  ON delay 
-  OFF delay 
-  Latching On delay 
-  ON/OFF delay 
-  Staircase lighting switch 
-  Convenience switch 
-  Interval time-delay relay 
-  Interval time-delay relay, edge-triggered 
-  Pulse generator 
-  Counter 
-  Elapsed time counter 
-  Trigger 
-  Trigger, analog 
-  Delta trigger 
-  Comparator, analog 
-  Analog value monitoring 
-  Amplifier 
NEW from firmware version 1.25: 
-  ramp function 
-  PI Controller 
-  Multiplexer, analog