Insys GSM LOGO 4.2 Compact 11-02-01-03-04.001 Manuale Utente

Codici prodotto
11-02-01-03-04.001
Pagina di 59
INSYS GSM 4.2 LOGO! 
 
HSComm 
Dezember 06 
 
39
 
 
5.8.1  Defining Values to be Utilized 
The first configuration step is to define which values of the PA buffer are to be 
utilized in the LOGO! control program. These values form the content of a PA-SMS 
and represent the basic set of values to be monitored. 
 
 
Double-clicking in the tree structure on the left opens the corresponding window 
(here, for example, the window for digital inputs). 
 
The check boxes for the utilized values must be selected; they appear green in the 
PA buffer overview in the right pane. 
 
5.8.2  Configuring Periodic PA-SMS 
If a periodic PA-SMS is to be sent, the 
corresponding check box must be 
selected on the “Periodic PA-SMS” 
menu. The timing of the scan intervals 
is entered in the “Polling Cycle” 
window. The recipient of the periodic 
PA-SMS must be entered in the “Target 
Number” window. 
 
5.8.3  Defining Actual Values 
To enable actual values of function blocks to be scanned via SMS using the INSYS 
GSM 4.2 LOGO!, the block numbers and function block type must be assigned 
from the LOGO! control program.