Toolcraft Laser rangefinder Reading range (max.) 70 m 107588 Manuale Utente

Codici prodotto
107588
Pagina di 108
52
23. Troubleshooting
Code
Cause
Solution
101
Batteries weak
Replace the batteries.
104
Calculation error
Repeat the process.
152
Operating temperature 
exceeded
Observe the correct operating 
temperature.
153
Operating temperature 
beneath the limit
154
Measurement range 
exceeded
Observe the correct 
measurement range.
155
Reflected signal too 
weak
Choose another measurement 
surface.
156
Reflected signal too 
strong
157
Measurement error or 
surface too bright
Darken the measurement 
surface or choose another 
surface.
160
Vibration too heavy
Hold the device still.
If the symbol 
 (5) appears on the left side of the display, there is 
a hardware error. Repeatedly turn the device on and off in such case. If 
the symbol 
 still appears, the device is defective.
24. Cleaning and maintenance
 • Never submerge the product in water or other liquids.
 • The product is maintenance-free. Clean the device housing using 
only a soft, dry cloth or brush. To clean the measurement sensor, 
use a small brush or cotton swab.