Insys GSM 4.2 Compact 11-02-01-03-04.002 Manuale Utente

Codici prodotto
11-02-01-03-04.002
Pagina di 89
Initial Operation 
 
INSYS GSM 4.2  
INSYS GSM 4.2 compact 
 
26
 
 
 
 
 
 
 
 
 
 
 
 
Sep-06
 
3.5.2  Initial configuration with AT commands 
You can perform the initial configuration alternatively with the software HSComm as 
described in the previous chapter. 
1. 
Start your terminal program or the terminal window of HSComm. 
2. 
Set the serial interface settings to the standard values: 19200 baud, 8 data bits, 1 
stop bit, no parity: 
AT**BAUD=19200 
AT**FORMAT=8N1 
3. 
If the INSYS GSM is in an undefined state, reset it optionally to the factory settings 
first: 
AT&F&WZ 
AT**DEFAULT 
4. 
Enter the PIN. 
Example: Entering the PIN 1234: 
AT**PIN=1234 
If the PIN of the SIM card is deactivated, enter only AT**PIN=
5. 
Check the field strength of the GSM signal: (see Chap. 3.9) 
AT**SIGNAL? 
The GSM signal should have a field strength of at least 12.  
For lower values or the value 99 you will need to change the antenna location. 
 
Note 
After changing the antenna location, wait 5 to 10 seconds. Only 
now will the INSYS GSM display the field strength correctly.