History 
The current values from the internal history list are read out and displayed. The INSYS 
GSM records the following events continuously in a ring buffer.  
The ring buffer always contains the last 200 entries. The buffer will be deleted when re-
setting to factory settings. The entries will be displayed in chronological order on max. 
4 pages. 
Export as text 
The displayed data can be stored as text file. Have this data ready for technical support. 
 
 
Meaning of the entries: 
Reason 
Detail 
Meaning 
RTC ERROR 
Internal real time clock is faulty (time stamp empty) 
RTC RESET 
The internal real time clock has been reset as the gold cap was dis-
charged (power reserve used up). Time stamp: 00:00:00 01.01.03 
GSM ERROR 
Instruction from controller to GSM engine could not be processed cor-
rectly (e.g. AT command, dial-up, SMS dispatch…) 
SIGNAL ERROR 
Field strength not ascertainable (
AT**SIGNAL?
: 99) 
LOGOUT 
GSM engine logged out (update interval like STATUS LED) 
LOGIN 
GSM engine logged in (update interval like STATUS LED) 
REMOTE PARAM 
Remote configuration started (*** detected) 
ALIVE 
Alive SMS process starts 
RESET  
Software/hardware reset 
SYSTEM 
POWER UP 
Power up; upon return of voltage 
SECURITY  DPW ERROR 
Wrong data password or timeout expired