Configuration 
 
INSYS Modem 56k UL
 
12   Juni 
05
 
Command Description 
ATP 
Select pulse dialing 
ATT 
Select tone dialing 
AT%Q 
Display phone connection quality 
ATS0 auto 
answer 
AT+VCID 
set caller ID (INSYS Modem 56k only) 
AT+VRID last 
received 
caller 
ID (INSYS Modem 56k only) 
AT\V connect 
messages 
ATX 
Extended result reporting, dial tone detection 
AT%L 
Display level of received signal 
AT&Z 
Store phone numbers 
A comprehensive description of all AT commands and parameters is available in the ad-
dendum „command overview“. 
4.4  Access Protection 
4.4.1  Password Protection 
With password set the modem is protected from unauthorized access 
• 
for incoming data connections 
• 
for remote control 
• 
for security callback 
4.4.2  Security Callback 
When the modem answers an incoming call the message “CONNECT” is followed by the 
messages “SECURITY CALLBACK” and “REMOTE PASSWORD:”. 
• 
If the password is wrong the modem immediately disconnects and stops an unau-
thorized access. 
• 
If the password is correct the modem reports "OK" to the calling terminal, disconnects 
and dials the phone number specified after 10 seconds. Up to 3 call attempts are exe-
cuted with 10 seconds breaks in between. 
• 
2 seconds after the connection the message “CALLBACK IN PROGRESS” is sent by the 
calling modem and the serial line is released for a standard data connection. 
Outgoing calls are not influenced by the security callback functionality.