Initial Operation 
 
INSYS Modem 56k UL
 
6   Juni 
05
 
 
3.3  Installation Steps 
1. 
Mounting on DIN rail: 
 
simply clip on 
2. 
Power supply: 
a)  Connect earth cable to GND 
b)  Connect power supply cable to 10..60 VDC 
Note:  Maximum ratings at pins 2 and 3 must not be exceeded!  
c)  Connect to power supply 
The power LED lights up on successful installation. 
3. 
Telephone network: 
a)  Plug the TAE cable into the middle of the RJ-45 socket on the front of the hous-
ing 
 
or alternatively 
 
install via screw terminal on the bottom according to description (b2, b1, a1, a2, 
NC).  
c)  connect cable to the TAE plug 
Disconnect the INSYS Modem 144/336/56K from the phone line immediately in case of 
any fault or functional irregularities – e.g. when the OFF-Hook-LED switches on immedi-
ately - and contact your service partner. In order to preserve your guarantee please do 
not open or interfere with the modem. 
4. 
Connecting PC/terminal: 
Plug the enclosed RS 232 interface cable into housing front and connect with 
PC/terminal. 
5. 
Checking successful installation: 
Execute a short test from your terminal program (e.g. HSComm terminal window, 
HyperTerminal, TeraTermPro, ProcommPlus). Enter the command “AT” and press 
the “ENTER” button. If “OK” appears on your screen the INSYS Modem 
144/336/56K has been successfully installed. 
6. 
Connection test: 
Start a connection from your terminal program: 
•  Dial the following number 0101901929 (ATDT0101901929
Attention: 
For PABXs which require a „0“ for connection set-up, please enter 
the following ATX3DT0,0101901929 
•  OFF-Hook-LED lights up 
•  Modem dials 
•  After some time (not more than 1 minute) the CONNECT message appears and 
the DCD LED switches on 