Chauvin Arnoux CA5233 Digital-Multimeter, DMM, 6000 counts CAT IV 600V P01196733 Scheda Tecnica
![Chauvin Arnoux](https://files.manualsbrain.com/attachments/1c6a0da915cf6503e82f46888dd01d308d767b5d/common/fit/150/50/2eac20890e32766c458ded9a5b257340fd3c97f9e976af4f4b7655116c90/brand_logo.gif)
Codici prodotto
P01196733
English
54 - 138
4.6 COMPLIANCE WITH INTERNATIONAL STANDARDS
Electrical safety :
Application of safety rules as per standard
EN-61010-1-Ed.2:2001.
EN-61010-1-Ed.2:2001.
1000V CAT-III - 600V CAT-IV.
Pollution level 2. Double insulation.
Electromagnetic
compatibility :
compatibility :
Compliant with standard EN-
61326/A2:2001
61326/A2:2001
Residential environment
Mechanical
strength :
strength :
Free fall: 1m (in accordance with standard
IEC-68-2-32)
IEC-68-2-32)
Degree of protection
of the housing :
of the housing :
IP54 as per EN 60529
4.7 VARIATIONS IN DOMAIN OF USE
Quantity of influence Range of influence
Influence
Temperature
0°C to + 50°C
V AC : 0.5%L/10°C
mV DC : 0.5%L/10°C
Ω
(R>20 M
Ω
) :
0.5%L/10°C
µF (C>50 µF) :
5%L/10°C
Frequency
1 to 3 kHz
V AC : 10%L + 1ct
5. MAINTENANCE
For maintenance, use only the replacement parts specified.
5.1 CLEANING
Disconnect all leads from the instrument and set the switch
to
to
.
Use a soft cloth, dampened with soapy water. Rinse with a
damp cloth.
damp cloth.
Dry thoroughly with a dry cloth or forced air before using
again.
again.