OPERATION 
21 
Wire Gauge Considerations 
 
Background 
Before connecting the input terminals to a 
current/voltage source, the wire gauge of the 
cables should be considered.  
 
It is essential that the current capacity of the 
cables is adequate. The rating of the cables 
must equal or exceed the maximum current 
input for the selected range. 
Recommended 
wire gauge 
 
 
 
Wire Gauge 
(AWG) 
Nominal 
Cross Section 
(mm
2
Maximum 
Current (A) 
20 
0.5 
 
18 
13 
 
16 
1.5 
18 
 
14 
2.5 
24 
 
12 
34 
 
10 
45 
 
10 
64 
 
16 
88 
 
25 
120 
 
32 
145 
 
50 
190 
 
00 
70 
240 
 
000 
95 
290 
 
0000 
120 
340 
WARNING 
Withstand voltage wire recommendations 
As the PCS-1000 is a CAT II instrument, please 
ensure that the insulation capacity of the test 
cables exceed the DUT output voltage when 
performing current measurement.