Insys Modem 56k small INT 2.0 11-02-01-01-43.003 Manuale Utente

Codici prodotto
11-02-01-01-43.003
Pagina di 97
INSYS Modem 56k small INT 2.0/USB 1.0 
AT Command Set 
June 06 
47 
Command 
Description 
AT*C 
Remote configuration password 
This password secures the remote configuration as well as incoming data connections 
(see AT*P) and security callback.  
OLD PASSWORD 
Requires the old password (default: QWERTY). Wrong input leads 
to ERROR.
 
NEW PASSWORD 
Enter the new password with 6 to 12 characters.
 
CONFIRM 
Repeat the new password. Wrong input leads to ERROR.
 
OK  
The password is immediately stored in the EEPROM. 
AT&C<n> 
DCD (CT109) behavior 
Behavior of the RS232 DCD output of the modem. 
AT&C0 
DCD is always ON 
AT&C1 
DCD follows the carrier signal of the phone line (default) 
AT+CMGF=<n> 
Set the SMS dispatch format with AT+CMGS 
AT+CMGF=0
 
Sets the PDU mode for the SMS dispatch via AT+CMGS (default). 
AT+CMGF=1
 
Sets the text mode for the SMS dispatch via AT+CMGS (default). 
 
 
AT+CMGS 
SMS dispatch directly via AT command 
Depending on the setting of AT+CMFG, the command AT+CMGS will have a different 
syntax. 
 
Setting AT+CMGF=1 (text mode): 
AT+CMGS="phone number" 
The modem returns the “>” character and awaits the SMS text (up to 160 charac-
ters), ending with an EOF character (0x1A or STRG-Z). 
Notes: 
Depending on the provider, the phone number must be entered in the format 
"0941xxxx" or "49941xxxx" (see AT*M and/or AT&Z2). 
- After the sending procedure was successful, the modem will return "+CMGS: 000
 
 
   
Setting AT+CMGF=0 (PDU mode): 
AT+CMGS=<PDU string length> 
The modem returns the character “>” and awaits the PDU string, ended with an 
EOF character (0x1A or STGR-Z). 
Notes: 
- Depending on the provider, the phone number must be entered in the format 
"0941xxxx" or "49941xxxx" (see AT*M and/or AT&Z2). 
- "Numbering Plan" is ignored. 
- The service center is defined by AT&Z0, the SCA field in the PDU string is ignored. 
- Message header, confirmation SMS and validity period are not supported. 
- Data coding scheme: Only the “default alphabet” is supported.
 
- After the sending procedure was successful, the modem will return "+CMGS: 
<MR>