Holzmann Maschinen H020300027 Scheda Tecnica

Pagina di 38
SAFETY 
 
HOLZMANN MASCHINEN Austria   www.holzmann-maschinen.at 
Seite 22
 
 
MAGNETBOHRMASCHINE / MAGNETIC DRILL     MBM 450LRE / MBM 600LRE
 
 
Hazard of electric shock  
Undetected malfunctions in the power supply and/or the connected wood working machine 
might  result  in  electric  shock  when  touching  the  machine.  Ensure  proper  electric 
installation, and let it check periodically by a trained electrician. 
 
 
Danger due to unintended machine start-up  
Eliminate  this  risk  by  disconnecting  the  machine  before  you  perform  any  checks  or 
activities on the machine. 
 
 
Hazard of inhaling toxic dust  
Especially  wood  dust  arising  from  chemically  treated  wood  and/or  lacquer/paint  are 
harmful when inhaled. Therefore wear a suitable breathing mask if required. 
 
 
These risk factors can be minimized through obeying all security and operation instructions, proper 
machine maintenance, proficient and appropriate operation by persons with technical knowledge and 
experience. 
 
11.6 
Rules of assenbly 
 
Know about the structure of the magnetic drill before use: electromagnetic suctorial cup, 
spot drilling and the operational function of driving. 
 
Make sure that the switch is off and the plug is pulled out before installing or taking down 
the aiguille. 
 
Rotate the handlweheel, check whether the electric drill can move up and down smoothly, 
raise the electric drill to the top position(Side lay the backout.) 
 
The  aiguille  must  be  sharp.  As  for  Morse  taper  shand  drill,  please  note  the  Tang  must 
insert into the drogue behind the gain when aiming at it. When disassembling the aiguille, 
insert  the  wedge  into  the  drogue  gain,  knock  the  hardhead  to  fall  with  a  hammer.(The 
aiguille must be sharp) 
 
After drill chuck clamps the aiguille, pick up the key wrench. 
 
Put the power line behind the machine at work, keep it away from the aiguille. 
 
The  switches  of  the  electric  drill  and  the  magnet  must  be  set    in  the  off  position  before 
connecting to the power. 
 
Fasten the safety belt when using the magnetic drill.