OPERATION 
 
HOLZMANN MASCHINEN Austria   www.holzmann-maschinen.at 
Seite 24
 
 
MAGNETBOHRMASCHINE / MAGNETIC DRILL     MBM 450LRE / MBM 600LRE
 
d. Repeat 1.c operation; 
e. Repeat the 1.d operation (note: No people stand under the magnetic drill when 
operating, in case of power cut.); 
f. Turn off the switch of the electric drill after the operation. Two men grasp the 
magnetic drill, untie the safety rope, turn off the switch of the magnetic drill, 
take off the magnetic drill. 
 
12.2.3  Working method on the top  
Note: It needs at least three men to operate and a person to monitor it . Or else, do not use this 
working method 
a. Repeat 2 (a.b.c) operation; 
b. Repeat 1(c.d)operation, (note: Take preventing measures to the drilled scrap 
iron.); 
c. Repeat 2(f) operation 
 
12.2.4  Other working methods 
The user can take other working methods depending on the field operation, and must take the 
safety into consideration. 
12.3 
Supplementary specification 
 
The ground can not have sundries. Keep it dry and clean. 
 
Keep the aiguille sharp. 
 
Keep the key wrench from teh collet. 
 
Do  not  press  the  drill  forcefully.  When  meeting  blocks  in  operation,  withdraw  the  drill in 
case that the drill overload. If the running velocity slows down, loosen the pressure. Cut 
off the power if the drill stops suddenly. 
 
Put the cable behind the machine at work, keep it away from the aiguille. 
 
Set the switch on the off position before plugging in. 
 
Do not extend or dismantle the cable. 
 
Being  absorbed  on  coarse  surface  may  affect  the  magnetic  power  of  the  magnetic  drill. 
Thereby, it is necessary to do experiment in advance in case of accident. 
 
Take  preventing  measures  in  common  places  before  using  the  magnetic  drill,  such  as 
insulating creepage protector(including creepage protecting plug and socket and so on). Or 
else, the user must wear insulating gloves and shoes or stand on the insulating mat. Fix 
rated  creepage  protector  of  30mA  with  no  more  than  0.1S  operate  time  in  good 
conducting places such as moist or metal framework. 
12.4 
Grounding device 
 
Keep  the  instrument  well  connected  to  the  ground  in  case  of  getting  electric  shock.  The 
grounding device should have standard wire, and be equipped with grounded to work with 
the  grounding  wire.  Do  not  connect  in  correctly  the  live  wire  to  the  joint  of  the  cycling 
wire. 
 
The circuit board connected to the ground must have connection to the turn-on grounding 
device  forever,  and  make  it  connected  with  the  ground  together  with  the  plugging  hole 
and lug fastened by the yellow and green wires. 
 
Only allow using standard extended cable. The cable must be  equipped with a grounding 
plug and then supply power to instruments if the cable is damaged, repair or change it.