BUILT-IN SELF-TEST (BIST) AND OUTPUT TEST 
The AD9609 includes a built-in test feature designed to enable 
verification of the integrity of each channel as well as to facili-
tate board level debugging. A built-in self-test (BIST) feature that 
verifies the integrity of the digital datapath of the AD9609 is 
included. Various output test options are also provided to place 
predictable values on the outputs of the AD9609.  
BUILT-IN SELF-TEST (BIST) 
The BIST is a thorough test of the digital portion of the selected 
AD9609 signal path. Perform the BIST test after a reset to ensure 
that the part is in a known state. During BIST, data from an internal 
pseudorandom noise (PN) source is driven through the digital 
datapath of both channels, starting at the ADC block output.  
At the datapath output, CRC logic calculates a signature from 
the data. The BIST sequence runs for 512 cycles and then stops. 
Once completed, the BIST compares the signature results with a 
pre-determined value. If the signatures match, the BIST sets Bit 0 
of Register 0x24, signifying the test passed. If the BIST test failed, 
Bit 0 of Register 0x24 is cleared. The outputs are connected 
during this test, so the PN sequence can be observed as it runs. 
Writing 0x05 to Register 0x0E runs the BIST. This enables the Bit 0 
(BIST enable) of Register 0x0E and resets the PN sequence 
generator, Bit 2 (BIST INIT) of Register 0x0E. At the completion of 
the BIST, Bit 0 of Register 0x24 is automatically cleared. The PN 
sequence can be continued from its last value by writing a 0 in 
Bit 2 of Register 0x0E. However, if the PN sequence is not reset, 
the signature calculation does not equal the predetermined 
value at the end of the test. At that point, the user needs to rely 
on verifying the output data. 
OUTPUT TEST MODES 
The output test options are described in Table 17 at Address 
0x0D. When an output test mode is enabled, the analog section 
of the ADC is disconnected from the digital back-end blocks 
and the test pattern is run through the output formatting block. 
Some of the test patterns are subject to output formatting, and 
some are not. The PN generators from the PN sequence tests 
can be reset by setting Bit 4 or Bit 5 of Register 0x0D. These 
tests can be performed with or without an analog signal (if 
present, the analog signal is ignored), but they do require an 
encode clock. For more information, see the AN-877 
Application Note, Interfacing to High Speed ADCs via SPI