b) Setting up a Master-Slave Chain
The effect light can be operated controlled by a DMX controller or in a master-slave chain. In that case, the
integrated controller of the master device controls the connected slave devices.
•  Connect the DMX OUT (3) port of the master device to the DMX IN (2) port of the first slave device.
•  Connect the DMX OUT (3) port of the first slave device to the DMX IN (2) port of the subsequent slave
device.
•  Proceed as described above with all remaining slave devices.
•  Plug an XLR plug with a terminating resistor into the DMX OUT (3) port of the last slave device (as descri-
bed in section „Connection of a DMX Controller“).
10. Mains Connection
  The mains socket to which the effect light is connected must be close to the device and easily 
accessible to quickly separate the device from the mains voltage in case of an error.
 
Do not let the mains cable come into contact with other cables.
 
Be careful when handling mains cables and mains connections. Mains voltage may cause po-
tentially fatal electric shock.
 
Make sure that no cables lie around openly. Install cables professionally to prevent accidents.
 
Before plugging in the mains plug, ensure that the device voltage indicated at the effect light 
corresponds to the available mains voltage. Do not connect the device if the indication does 
not correspond to the available mains voltage. Incorrect supply voltage may lead to irreparable 
damage to the device and danger to the user.
•  Connect the mains cable low-voltage plug to the mains connection (1) at the device.
•  Plug the mains plug of the mains line into a grounded socket.