16 
Copyright © 2007, TRINAMIC Motion Control GmbH & Co. KG 
 
Therefore this parameter has to be stored correctly in EEPROM before power on! Do not 
enable this mode, before the parameter has been set correctly. Mode 4 helps for the very 
first initialization of this mode. 
 
Mode 4  helps to do a first initialization and tuning of mode 3. It searches for the N-channel 
reference point first, and then does a mode 2 initialization to determine the correct setting 
for the “Actual Commutation Offset”. The encoder N-channel polarity has to be high active 
for this mode (the actual setting of the encoder null polarity has no influence in this mode), 
and, additionally, you have to specify the polarity of the encoder A- and B-channel upon N-
channel activity using the setting “Encoder Null Polarity”, bits 1 and 2. The correct setting of 
this depends on the encoder. If the N-channel referencing fails, the motor does two full 
rotations and then stops. Try again with reversing the “Encoder Null Polarity”. After 
successfully initializing the “Actual Commutation Offset”, you can try moving the motor and 
tune the offset, if desired. Then store the offset and switch to mode 3. If any encoder errors 
are flagged during operation of the motor, retry with a modified setting for A- and B-
channel polarity. 
 
Attention:   Initialization modes 1 to 4 apply a high current to the motor for a few seconds. Be sure 
to parameterize the initialization current correctly (i.e. not more than 2* the maximum 
rated motor current) before first powering on the unit. 
 
The quality of the initialization phase result can be checked by rotating the motor left and right at the 
maximum velocity (use a velocity setting slightly higher than the motor can follow). Maximum velocity 
for left and right direction shall not differ by more than a few percent. Also make some checks if 
results are reproducible.  
Whenever changing one of these parameters, re-power the unit to restart initialization phase! 
5.3 Encoder 
setting 
The N-channel (index channel) of the encoder is not required for motor operation, but it is very good 
for motor initialization, because it gives an absolute and exact reference point. So, the motor 
initialization modes 3 and 4 use the N-channel for motor initialization. Behavior of the N-channel 
signal is very dependent on the encoder type and has to be taken into account for the setting of the 
TMCM171 encoder interface. Please refer to the following figure for correct setting of the Encoder Null 
Polarity flag.  
A wrong setting may either hinder the module from initializing the sine mode, or might lead to the 
Encoder Error flag being set, in spite of correct encoder function. 
 
zero event
Enc-A
Enc-B
Enc-N
(index)
Set Encoder Null
Polarity to
binary 011
Set Encoder Null
Polarity to
binary 001
zero event
CW turn
CCW turn
CW turn
CCW turn
0
1
0
0