Keba 86.875 Electric Cars KEBA 86.875 Electric Cars N/A Silver, Grey Silver, Grey 86.875 Scheda Tecnica

Codici prodotto
86.875
Pagina di 48
Further technical instructions
 KeContact 
P20 
44 
Installation
 manual, Version: 1.41 / Article no.: 90064 
 
© KEBA 2012-2013 
5.5  Technical data 
 
Electrical data 
Cable feed: 
Surface cable routing or flush-type cable routing 
 
Mains connection cross-section: 
Minimum cross-section 
(depending on the cable and the line length): 
- 5 x 2.5 mm² (16A nominal current) 
- 5 x 6.0 mm² (32A nominal current) 
 
Mains supply terminals: 
Connection line: 
- inflexible (min.-max):   0.2 – 16 mm² 
- flexible (min.-max):   0.2 – 16 mm² 
- AWG (min.-max):  
24 – 6 
- flexible (min.-max) with wire end sleeve 
  without/with 
plastic 
sleeve: 
 
  
0.25 – 10 / 0.25 – 10 mm² 
 
Mains supply terminals temperature rating: 
 
105°C 
 
Nominal current  
(configurable connection values): 
10A, 13A, 16A, 20A, 25A or 32A 
3-phase or 1-phase 
 
Mains voltage (Europe): 
230V 
230/400V 3N~ 
 
Line frequency: 
50Hz / 60Hz 
 
Overvoltage category: 
III according to EN 60664 
 
Rated short-time withstand current: 
< 10kA effective value according to EN 61439-1 
 
Fuse protection (in the house installation): 
The fuse protection must occur according to the 
locally valid regulations, dependent on the socket 
versions / cable versions (see type plate). 
 
Residual current circuit breaker  
(in the house installation): 
RCD I
∆N
=30mA Type A, sensitive to pulse current 
Dimension I
according to the fuse protection 
 
Socket versions: 
Type 2 standard socket: 32A / 400 V
AC
 
according to EN 62196-1 and VDE-AR-E 2623-2-2 
 
Cable versions: 
 
(rating see type plate) 
Type 1 cable: up to 32A / 230 V
AC
 
according to EN 62196-1 and SAE-J1772 
 
Type 2 cable: up to 32A / 400 V
AC
 
according to EN 62196-1 and VDE-AR-E 2623-2-2 
 
Equipment class: 
 
IP protection rating for device: 
IP54