4. Wire Size Selection   
All electrical systems lose energy due to resistance in conductors: the wires. 
      • The larger the wire is , the less resistance and the loss are 
      • Resistance losses will also increase with increasing current; therefore, if you installation is at a high wind site, it may be worthwhile to go with a larger size wire to lower the loss 
and enhance the output of wind turbine. 
      • Conversely, in low wind sites it may not be cost effective to increase the wire size since power production will be comparative lower. 
To determine the wire size, measuring the distance from the batteries to wind turbine is necessary, be sure to include height of the tower. Refer to the appropriate chart for your system 
voltage and select the wire size. The following wire sizes provide maximum annual energy losses of 3% for most sites.                               
 
HY-400/12V system 
                             
                                         
Distance from wind generator 
to controller 
0—10m 11—20m 
21—30m  31—40m  41—50m 51—60m 61—70m 71—90m 
AWG/Metric Wire Size 
mm²  
9/6 mm² 
5/16 mm² 
4/21 mm² 
2/33 mm² 
1/42 mm² 
1/42 mm² 
0/53 mm² 
00/67 mm² 
 
HY-400/24V system 
                                     
Distance from wind generator 
to controller 
0—10m 11—20m 21—30m  31—40m  41—50m 51—60m 61—70m 70—100m 
AWG/Metric Wire Size   
mm²  
11/4 mm² 
9/6 mm² 
8/8 mm² 
7/10 mm² 
6/13 mm² 
5/16 mm² 
4/21 mm² 
3/26 mm² 
 
HY-400/48V system
                                     
 
Distance from wind generator 
to controller 
0—10m 11—20m 
21—30m 31—40m  41—50m 51—70m 
71—90m 91—110m 
AWG/Metric Wire Size 
mm²  
13/2.5 mm² 
13/2.5 
mm² 
13/2.5 
mm²  
13/2.5 mm² 
11/4 mm²   
10/5 mm²   
9/6 mm²   
8/8 mm²