5. Troubleshooting
5.1 Wind Turbine Troubleshooting
5.1.1 Wind Turbine Vibration
Wind turbine vibration is mainly caused by the following factors:
1) The blades mounting bolts get loose and need to be tightened;
2) The surface of blades gets frozen and needs to be removed;
2) The surface of blades gets frozen and needs to be removed;
3) The blades have been distorted, defected and need to be replaced.
4) The tower is not strong enough or guy rope gets loose, and needs to be reinforced or tightened;
5) The wind turbine operates lacking phase, need to check if the three-phase output voltage is balanced or not by testing with multimeter.
5) The wind turbine operates lacking phase, need to check if the three-phase output voltage is balanced or not by testing with multimeter.
IMPORTANT: Turbine operation should be stopped as soon as abnormal vibration happened till problems solved to avoid personnel or machine damaged.