a power outage.
1
Plug the power cable of the UPS to a wall socket.
2
Connect the AC cable of the TeraStation to the UPS.
3
Connect the UPS and TeraStation using a USB cable or serial cable.
4
Turn on the UPS, then the TeraStation.
5
In Settings, click Management.
6
Click
to the right of “UPS Sync”.
7
Click Edit.
8
Configure the desired settings, then OK.
Notes:
• If the TeraStation is connected directly to a UPS, select “Sync with UPS connected to this TeraStation”. If a differ-
• If the TeraStation is connected directly to a UPS, select “Sync with UPS connected to this TeraStation”. If a differ-
ent TeraStation is connected to the UPS, select “Sync with UPS connected to another TeraStation on the same
network” After making this selection, enter the IP address of the TeraStation that will be the sync source in “Other
TeraStation’s IP Address”.
network” After making this selection, enter the IP address of the TeraStation that will be the sync source in “Other
TeraStation’s IP Address”.
• When the TeraStation is rebooted after an automatic shutdown (such as from a power outage or power supply
problem), verify that the power supply has been restored. If the TeraStation is turned on while it is still running on
the UPS and without the power supply restored, automatic shutdown is not performed, even after the specified
time has elapsed.
the UPS and without the power supply restored, automatic shutdown is not performed, even after the specified
time has elapsed.
• If the power supply from the UPS to the TeraStation is stopped and restarted when UPS recovery is enabled, the
TeraStation is automatically restarted.