Volume 2—Gigabit Ethernet (GbE) Controller—C2000 Product Family
Architectural Overview
Intel
®
Atom™ Processor C2000 Product Family for Microserver
Datasheet, Vol. 2 of 3
September 2014
208
Order Number: 330061-002US
11.5.13.2 NC-SI and REF_CLK
The NC-SI is an optional connection to an external BMC defined by the Distributed
Management Task Force (DMTF) protocol defined in the Network Controller Sideband
Interface (NC-SI) Specification (DSP0222). The It operates as a single interface with an
external BMC, where all traffic between the GbE controller and the BMC flows through
the interface. The GbE controller interface supports the standard DMTF NC-SI protocol
and supports both pass-through traffic between the BMC and integrated GbE controller
LAN functions as well as configuration traffic between the BMC and other SoC internal
units as outlined in the Intel
®
Atom™ Processor C2000 Product Family Integrated GbE
Controller Programmer’s Reference Manual (PRM).
The NC-SI Specification describes a 50-MHz clock REF_CLK that is used by all the NC-SI
devices. This clock must be provided by the platform board or one of the NC-SI
devices. As an option the SoC integrated GbE controller can provide this 50-MHz
REF_CLK. The internal circuitry of the SoC calls this signal NCSI_CLK_OUT which is
internally connected to the NCSI_CLK_IN signal pin P50. The
register
in EEPROM at 16-bit word location 21h, contains the NC-SI Output Clock Disable (bit
13). When this bit is 0, the GbE controller drives the 50-MHz NC-SI REF_CLK
(NCSI_CLK_OUT) via pin P50. When this bit is 1, the GbE controller does not drive the
NC-SI clock and pin P50 is an input, NCSI_CLK_IN. The default setting of bit 13 is 0. If
this bit is 0 (NCSI_CLK_OUT enabled), the Power Down Enable (bit 15) of
Note:
If the GbE Controller is configured to provide the 50-MHz NC-SI clock signal to the rest
of the platform board, then the SoC Soft Strap GBE_ALL_Disable must be a “0” (device
is enabled).
Note:
If NC-SI is not used, then
register bit 13 must be set
(NCSI_CLK_OUT disabled).
register bits 15 and 14 control the drive strength of the GbE
controller’s NC-SI Clock (NCSI_CLK_OUT) Pad Drive Strength and NC-SI Data
(NCSI_CRS_DV and NCSI_RXD[1:0]) Pad Drive Strength respectively.
The Multi-Drop NC-SI (bit 11) of the Common Firmware Parameters 2 located in the
Firmware section of the EEPROM defines the NC-SI topology as Point-to-Point (bit 11 =
1) or Multi-Drop (bit 11 = 0, the default setting).
The GbE controller dynamically drives its NCSI_CRS_DV and NCSI_RXD[1:0] output
signals as required by the sideband protocol:
• On power-up, the SoC floats the NC-SI outputs except for NCSI_CLK_OUT.
• If the GbE controller operates in Point-to-Point topology mode, it starts driving the
• If the GbE controller operates in Point-to-Point topology mode, it starts driving the
NC-SI outputs some time following power-up.
• If the GbE controller operates in a Multi-Drop topology mode, it drives the NC-SI
outputs as configured by the BMC.
Additional information is available in the Intel
®
Atom™ Processor C2000 Product Family
Integrated GbE Controller Programmer’s Reference Manual (PRM).
Electrical and timing specifications are in
.
Board design guidelines for both SMBus and NC-SI are given in the Intel
®
Atom™
Processor C2000 Product Family Platform Design Guide (PDG).