Hunter Engineering Quick Tread Foglio Delle Specifiche

Pagina di 2
Form 6893-T, 02-15bCopyright © 2015, Hunter 
Engineering Company
OPTIONAL IN-GROUND CONDUIT SPECIFICATIONS 
 Additional conduit 
from pedestal to console for a 
Burndy cable (max length of 
75 feet), and two Cat5 cables 
may also be desired. Air 
supply to pedestal should also 
be considered.
Quick Tread - Stand Alone
Surface-Mounted
3 1/2 in.
32 in.
23 1/2 in.
67 1/4 in.
(5 ft. 7 1/4 in.)
STACK HEIGHT
QUICK TREAD DIMENSIONS
QUICK CHECK DIMENSIONS
67 in. 
(5 ft. 7 in.)
87 in. 
(7 ft. 3 in.)
24 in. 
(2 ft.)
36 to 96 in. 
(3 ft. to 8 ft.)
44 in. 
(3 ft. 8 in.)
39 in. 
(3 ft 3 in.) 
5 in.
17 3/8 in.
5 in.
 
14 7/8 in.
PEDESTAL
34 1/2 in.
ROUTE 3 IN. MIN. DIAMETER
CONDUITS (OR EQUIVALENT
CLOSED CHANNEL) AS SHOWN
CONDUIT UNDER RAMPS:
1 INCH ABOVE GROUND
4 INCHES FROM EDGE
ROUTE CONDUIT FROM PEDESTAL TO
FIRST RAMP. ROUTE A
FIRST RAMP TO SECOND RAMP.
SECOND CONDUIT
FROM
4 in
4 in.
4 in.
1 in.
1 in.
PEDESTAL
RAMP ONE
RAMP TWO
96 in. (8 ft.) is the maximum  
distance between the middle of the  
pedestal and nearest edge of Quick 
Tread. Any further will reduce max  
vehicle test entry speed.