SERVICE (cont.)
Location:
 
The control thermostat is located on the rear of 
the hood to the right of the tank.
Test Procedure:
1.  Disconnect the brewer from the power source and 
remove the black wire from the control thermo-
stat.
2.  With  a  voltmeter,  check  the  voltage  across  the 
black wire removed from the control thermostat 
and the white wire on the tank heater terminal. 
Connect  the  brewer  to  the  power  source.  The 
indication must be 120 volts ac.
3.  Disconnect the brewer from the power source.
If voltage is present as described, reconnect the black 
wire and proceed to #4.
If voltage is not present as described, refer to the Wir-
ing Diagram  and check the brewer wiring harness.
4.  Remove the blue wire from the control thermo-
stat.
5.  With  a  voltmeter,  check  the  voltage  across  the 
exposed terminal of the control thermostat and 
the white wire on the tank heater terminal when 
the control thermostat is turned “ON” (fully clock-
wise). Connect the brewer to the power source. 
The indication must be 120 volts ac. Voltage must 
not be indicated across these terminals when the 
thermostat  is  turned  “OFF”  (fully  counterclock-
wise).
6.  Disconnect the brewer from the power source.
If voltage is present as described, reconnect the  blue 
wire, the control thermostat is operating properly.
If  voltage  is  not  present  as  described,  replace  the 
control thermostat.
Removal and Replacement
1.  Remove both wires from the control thermostat 
terminals.
2.  Remove  the  thermostat  bulb  by  firmly  pulling 
up on the capillary tube at the tank lid. This will 
disengage the grommet from the tank lid.
3.  Remove the two #8-32 screws holding the control 
thermostat to the brewer housing.
4.  Slide the grommet to the red mark on the capillary 
tube.
5.  Insert the bulb through the hole in the tank lid and 
press the grommet firmly and evenly so the groove 
in the grommet fits into the tank lid.
6.  Carefully bend the capillary tube so the tube and 
bulb inside the tank are in a vertical position.
NOTE - Make sure the capillary tube is away from any 
electrical termination and is not kinked.
7.  Fasten the new control thermostat to the brewer 
housing.
8.  Refer to FIG. 7 when reconnecting the wires.
9.  Readjust the control thermostat dial as required.
FIG. 6 CONTROL THERMOSTAT
P2172.80
10179 060100
CONTROL THERMOSTAT
BLU to Limit Thermo-
stat
BLK to Cordset
FIG. 7 CONTROL THERMOSTAT TERMINALS