SERVICE (cont.)
LIMIT THERMOSTAT
Location:
 
The  limit  thermostat  is  located  on  the  tank  lid 
between the tank heater terminals.
Test Procedure:
1.  Disconnect the brewer from the power source and 
remove the blue wire from the limit thermostat.
2.  With  a  voltmeter,  check  the  voltage  across  the 
blue wire removed from the limit thermostat and 
the white wire on the tank heater terminal when 
the control thermostat is turned “ON” (fully clock-
wise). Connect the brewer to the power source. 
The indication must be 120 volts ac.
3.  Disconnect the brewer from the power source.
PN:
 65
8
FIG. 10 LIMIT THERMOSTAT
P1983.40
If voltage is present as described, reconnect the blue 
wire and proceed to #4.
If voltage is not present as described, refer to the Wir-
ing Diagram and check the brewer wiring harness.
4.  Remove  the  black  wire  from  the  limit  thermo-
stat.
5.  With  a  voltmeter,  check  for  voltage  across  the 
exposed terminal of the limit thermostat and the 
white wire on the tank heater terminal when the 
control thermostat is turned “ON” (full clockwise). 
Connect  the  brewer  to  the  power  source.  The 
indication must be 120 volts ac.
6.  Disconnect the brewer from the power source.
If voltage is present as described, reconnect the black 
wire, the limit thermostat is operating properly.
If voltage is not present as described, replace the limit 
thermostat.
Removal and Replacement:
1.  Remove  both  wires  from  the  limit  thermostat 
terminals.
2.   Carefully slide the limit thermostat out from under 
the retaining clip.
3.  Carefully slide the new limit thermostat into the 
retaining clip.
4.  Refer to FIG. 11  when reconnecting the wires.
FIG. 11 LIMIT THERMOSTAT TERMINALS
P1984.60
BLU to Control
Thermostat
BLK to Tank 
Heater
10179 060100