5    Maintenance 
5.3 
Replacing Stator / Wiper Ring 
Preparation 
•  Switch dispensing station off and safeguard against unauthorised use. 
•  Disconnect compressed air supply. 
•  Remove product container – see also Section 3.5. 
5.3.1 Unscrew 
pump 
unit 
 
•  Raise Pump Unit (D) to top position (direction of arrow) and hold. 
•  Lightly hand tighten the locking screw (G). Pump unit is locked into place in top 
position. 
•  Disconnect plug connection (A) pressure switch. 
•  Disconnect plug connection (B) pump motor. 
•  Unscrew pressure line (H). 
•  Hold pump unit and remove screws (E).