Znyx Networks bh5700 Manuale Utente

Pagina di 359
6. Isolation Transformer
13. Isolation Transformers
7. Power Supply
14. 4 Port PHY 
Hardware Subsystem
In the following tables, refer to the identified component-area numbers on indicated in the 
pictures in the proceeding section. The indications of malfunction may be identified either during 
normal operation, or in response to a specific test. The various tests that may be initiated are 
shown in subsequent sections.
The information is equally applicable to both the Base Interface and the Fabric Interface switch 
subsystems unless otherwise noted.
Base
ZMC 0 
#
ZMC 1 
#
Hardware 
Subsystem
Indications of Malfunction
4
3
CPU
A CPU failure may be indicated by any of the 
following:
A failure to run the Power-On-Self-
Test (POST)
A failure to boot the OpenArchitect 
kernel
Kernel panics
Loss of CPU response sometime after 
operation is initiated 
5
3
RAM
The Ethernet Switch Blade uses SDRAM for 
the primary CPU memory system. A failure of 
RAM will generally cause any of the 
following:
Kernel panics
Loss of CPU response
Unexplained software failures 
1
8
ROM
The Flash ROM subsystem on the Ethernet 
Switch Blade is used only on boot-up. The 
contents are decompressed and copied to RAM 
memory for further use. A ROM failure will 
generally cause a failure in the boot process. 
9, 10
6, 7
Switch Fabric
The Ethernet Switch Blade has four switch 
fabric chips: 2 for the Base Interface with 24 
ports, and 2 for the Fabric Interface with 48 
ports. A Switch Fabric failure may result in 
Ethernet Switch Blade User's Guide
release  3.2.2j
page 176