Znyx Networks bh5700 Manuale Utente

Pagina di 359
Base
ZMC 0 
#
ZMC 1 
#
Hardware 
Subsystem
Indications of Malfunction
any of the following indications:
Error message via OpenArchitect due 
to inability to access the registers 
within the switch chip, or a failure of 
DMA transfers.
Loss of switch functionality, such as 
the inability to forward packets, or 
forwarding packets in error.
8
12
Power Supply
A power-supply failure will generally result in 
lack of boot activity.
3, 6, 12, 
13, 16, 
17 
2, 4, 6, 
13, 15
1, 2, 4
Ethernet PHYs 
& Transformers 
An error in the PHY will generally result in 
loss of link, or Ethernet data transfer errors 
such as Checksum and Frame Alignment.
Note that for ATCA 3.1 Fabric ports, there is 
no separate PHY devices or transformers; the 
SerDes interface in the switch chips are used 
instead.
9
FPGA
Most FPGA failures will result in the CPU 
failing the boot process. 
BOOT ROM
If the Boot ROM fails or is not programmed, 
there will be no boot activity on the console 
port after power up. 
Network Cable  Network cable failures will result in loss of 
link or loss of data packets.
7
IPMI Controller If the IPMI controller is not functioning, the 
Ethernet Switch Blade board will not power up 
when inserted into a powered-up chassis.
This condition may also result from a failure 
within the ATCA Shelf Manager (ShMM) or if 
the ShMM determines that the chassis cannot 
support the Ethernet Switch Blade. 
Testing the FlashROMs
The FlashROMs (device 1 and 2) contain compressed images of the OpenArchitect operating 
system. FlashROM device 1 is the primary operating system image. If OpenArchitect has 
successfully booted, then FlashROM device 1 is fully operational. 
To test FlashROM device 2, set the Ethernet Switch Blade to load the backup image on reboot. 
For instructions on temporarily booting from FlashROM device 2, see the section on Booting the 
Ethernet Switch Blade User's Guide
release  3.2.2j
page 177