NOTE:  Zero input corresponds to zero screw speed and no additive dosing.  Maximum input 
corresponds to maximum screw speed. 
 
NOTE:  If a 0-10kHz frequency input is used, it must be a square wave with an amplitude of 
12VDC.  The shape of the signal is important, especially above 7,000Hz. 
 
 
 
 
 
 
 
 
J12-4   
     _ 
 
 
 
 
 
 
 
J12-3    
     + 
 
 
 
 
0-10vdc or 0-20ma 
  Extruder 
output  Digital Dosing controller 
 
 
(diagram of frequency inputs) 
Figure 6.  Frequency Inputs 
 
5.  Make sure the unit is turned OFF before plugging it in.  The switch toward the rear of 
the controller unit should be in the OFF, or “O” position.  Standard operation voltage is 
110 or 220 VAC, 50/60 Hz, single-phase power.  Special voltages are available, refer to 
voltage label on the feeder to determine the correct operating voltage. 
3.2 Initial Operation 
 
The control system is factory-programmed. Nevertheless, specific values need to be predefined 
or checked prior to operation (basic parameter settings). The input values will be saved and will 
still be available if the unit is switched off, or a power failure occurs. Please refer to Appendix 
B for these values. Extrusion operations require a “span factor” to be entered into the basic 
settings. Please refer to Appendix B. 
 
Prior to putting your new Digital Dosing Additive Feeder on-line: 
•  You must enter a recipe and calibrate the feeder.