Sterling Doll BF3-600 Manuale Utente

Pagina di 67
Digital Dosing Units 
37
5.  Remove the dosing hopper from the dosing unit. 
6.  Dismantle the dosing unit and remove the scraper (D). 
7.  Loosen the two hexagon socket screws (B, M6 x 30) on the top side of the dosing disc 
(A). 
8.  Loosen the center hexagon socket screw (C, M6 x 12) and replace by an M6 x 60 screw. 
9.  Lift the dosing disc (A) from the 
dosing unit housing (B) by this 
screw. 
10. Clean the scraper using a cotton 
cloth. 
11. Clean the dosing hopper and the 
dosing disc in soapy water. 
12. The dosing unit housing may also 
be cleaned with soapy water. 
13. Ensure that soapy water does not 
enter ball bearings. 
14. Dry all parts thoroughly. 
Installing the Dosing Station 
1.  Place the dosing disc in the dosing unit housing. 
2.  Remove the screw (M6 x 60). 
3.  Screw the dosing disc in place by means of 2 hexagon socket screws (M6 x 30). 
4.  Mount the center hexagon screw (M6 x 12). 
5.  Install the scraper and then the dosing unit. 
6.  Turn the dosing disc to check for smooth movement. 
7.  Position the dosing hopper on the dosing unit. 
8.  Tighten the profile clamp.