Sterling Doll BF3-600 Manuale Utente

Pagina di 67
Digital Dosing Units 
39
 
Installing Different Types of Dosing Discs 
Dosing discs of the same type may be exchanged for each other without any problems. If dosing 
discs with a different compartment number are installed, this has to be entered in the control 
system! 
1. Enter the (preliminary) calibration value of the freshly installed dosing disc (* = bulk 
density 550g/l, ** = bulk density 700g/l). 
2. Execute “calibration” to determine the final calibration value
5.5  Removing/Replacing the Scraper in the DT Dosing Station 
 
1.  Empty the dosing station. 
2.  Open the profile clamp (C) of the 
dosing container. 
3.  Remove the profile clamp (C) 
4.  Remove the dosing container (B) 
along with the dosing hopper (A). 
 
5.  Loosen the 3 plastic screws on the 
stripper (DT-t: metal screws). 
6.  Remove the scraper and holding 
plate. 
7.  Install the new scraper along with the holding plate. 
8.  Tighten down the 3 plastic screws. Make sure that the stripper is fitted parallel to the 
dosing plate (Use only plastic screws (DT-t: metal screws).