PASCO Specialty & Mfg. 1 MHz 2-channel Voltage Sensor PS-2190 Manuale Utente

Pagina di 4
®
1  M H z  2 - c h a n n e l  V o l t a g e  S e n s o r
PS-2190
4
Trigger In-Out
The PS-2190 has two BNC connectors on the rear panel labeled 
Trigger In and Trigger Out. By connecting the Trigger Out of one 
PS-2190 to the Trigger In of a second PS-2190, the two sensors 
are time synchronized and four channels can be measured. Since 
the Xplorer GLX can currently only display two channels in 
Scope Mode, this feature is for future use.
Basic Specifications
Suggestions
Measure the voltage of a resistor-inductor-capacitor (RLC) 
circuit as an input AC voltage sine waveform ranges from 
below resonant frequency to above resonant frequency. 
Measure the voltage of a resistor-inductor (RL) circuit with 
an input AC voltage square waveform at 50 Hz.
Measure the voltage of a resistor-capacitor (RC) circuit as 
the capacitor charges and discharges through the resistor.
RLC Circuit
RL Circuit
RC Circuit
Technical Support
For assistance with any PASCO product, contact PASCO at:
For more information about the 1 MHz 2-channel Voltage Sensor 
and the latest revision of this Instruction Sheet, visit:
www.pasco.com/go?PS-2190
Limited Warranty
For a description of the product warranty, see the 
PASCO catalog.
Copyright
The PASCO scientific 012-10253A 1 MHz 
2-channel Voltage Sensor Instruction Sheet is copyrighted with all rights 
reserved. Permission is granted to non-profit educational institutions for 
reproduction of any part of this manual, providing the reproductions are 
used only in their laboratories and classrooms, and are not sold for profit. 
Reproduction under any other circumstances, without the written consent 
of PASCO scientific, is prohibited.
Trademarks
PASCO, PASCO scien-
tific, DataStudio, and PASPORT are trademarks or registered trademarks 
of PASCO scientific, in the United States and/or in other countries. All 
other brands, products, or service names are or may be trademarks or 
service marks of, and are used to identify, products or services of, their 
respective owners. For more information visit www.pasco.com/legal.
Channels
two, differential
Maximum Sample Rate (Burst 
Mode)
1 million samples per second
Maximum Sample Rate 
(Continuous Mode)
20,000 sample per second
Input Voltage Ranges
±10 V, ± 1 V, ± 0.1 V full scale
Resolution
12-bit analog-to-digital converter, 
5 mV at ±10 volts
Analog Bandwidth
120 kiloHz (-1 dB) typical
Absolute Maximum Input 
Voltage Without Damage
45 volts
Figure 8: Rear Panel
Address: PASCO scientific
10101 Foothills Blvd.
Roseville, CA 95747-7100
Phone:
+1 916-786-3800 
(worldwide)
800-772-8700 (U.S.)
Fax:
(916) 786-7565
Web:
www.pasco.com
E-mail: