NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 101
Blind Transfer To Attendant
B-17
Programming
STEP 1:
ASYD
- System 1, Index 17, Bit 4: (1) Blind Transfer to Attendant In Service.
System Data 2, Index 1, Bit 0 and Bit 1: (1).
STEP 2:
ASFC
- Cancel the restriction of Blind Transfer to Attendant from SFC of the station.
(SFI = 103, RES = 1).
STEP 3:
ANPD
- 0 = Hooking (H) NND = 1.
STEP 4:
ASPA
- 0 = Hooking (H) SRV = SSC (Service Code), SID = 2.
FCCS Programming 
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
Note
STEP 1:
ANPDL
- 0 = Hooking (H), NND = 1.
STEP 2:
ASPAL
- 0 = Hooking (H) SRV = SSC (Service Code), SID = 2, FPC = “x”.
Note:
When using ASYDL or ASYDN to program an FCCS feature, the basic programming of ASYD is required
in addition to ASYDL or ASYDN.