NEC 2400 PX Manuale Utente

Pagina di 1089
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 251
Call Block
C-150
Programming (cont’d)
STEP 5:
ADSL
- Assign the soft key data of Call Block for D
term
according to the following parameter:
SKP = 0-15 (Soft Key Pattern)
SN = 0, 1, 4 (Call Situation Number)
SKN = 1-16 (Soft Key Number)
FKY = 128 (Call Block Key)
STEP 6:
ADKS
- Assign the soft key data of Call Block for D
term
according to the following parameter:
TN = Tenant Number
STN = Station Number
SKP = 1-15 (Soft Key Pattern of Call Block assigned in ADSL)
LKP = 1-2 (Location of Key Pattern)
PG = 0/1 (Soft Key/Feature Key is allocated for Page Change Key)
STEP 7:
ASYD
- Assign the routine diagnosis program start time System Data 1, Index 87: hour, Index 88:
minutes
System Data 1, Index 90, Bit 1=1: Routine Backup is to be executed
System Data 1, Index 304, Bit 6=1: Data Backup of Call Block
FCCS Programming 
No unique programming is required for the FCCS network.