NEC 2400 PX Manuale Utente

Pagina di 1089
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 559
Outgoing Trunk Queuing - D
term
O-2D
FCCS Programming (cont’d)
System Data 1, Index 41: Designate the Trunk Queuing Override Timer
Index 68, b3:
Enables automatic cancel timer
0/1:
-/Automatic cancel timer is Available
Index 159:
Designate Automatic Cancel Timer
STEP 2:
ASPAN
- These data must be assigned to the NCN.
TN:
Tenant Number
ACC:
Access number
CI:
B = Busy (for Entry), N = Normal (for Cancel)
SRV:
SSC
SID:
19 = OG Queuing-Entry
SID:
20 = OG Queuing-Cancel
STEP 3:
ANPDN
- These data must be assigned to the NCN.
TN:
Tenant
1st DC:
1st Digit
CI:
Normal (N), Hooking (H) and Busy (B)
NND:
Number of Necessary Digits
BLF:
Busy Lamp Field
STEP 4:
ARTDN
- These data must be assigned to the NCN.
LGRT:
Logical Route Number
Assign CDN 9:TQ, Trunk Queuing Service = 1
Note 1:
When using ASYDL or ASYDN to program an FCCS feature, the basic programming of ASYD is required
in addition to ASYDL or ASYDN.
Note 2:
The current data should also be set in addition the above-mentioned command.
The command to be set to the node that accommodates the trunk: ARTD
The command to be set to all the nodes: ASFC, AKYD, ASPA