NEC 2400 PX Manuale Utente

Pagina di 1089
NEAX2400 IPX Feature Programming Manual
Page 580
NDA-24297, Issue 1
P-4
Pushbutton Calling
Programming (cont’d)
System Data 2, Index 2, Bit 0. Type of sender signal for station? 0/1: DP/PB. Assign as appropriate.
(This data will only be used if the ARTD data of a specific route is assigned as DP/PB.)
System Data 3, Index 11. Normally assign data 00H for 128 milliseconds.
STEP 2:
ASDT
- Assign D
term
, single-line stations, a Telephone Equipment Class (TEC) of 2; push button
(PB), TEC = 3, or Dial-Pulse/ Push button, (DP/PB).
STEP 3:
ATRK
- Assign Originating Register Trunks (ORT) to the system in a quantity calculated from
expected traffic. Registers are located on levels 0-3 of any 8RST circuit card.
Also, senders must be assigned to the system in a quantity calculated from expected traffic. Senders
are located on levels 4-7 of any 8RST circuit card.
RT:
Route Number
Trunk Route Number
Intra-office Route Number (901-931)
901-ATT
912-ORT for ATT
902-ORT
913-TCFT for ATT
903-IRT
915- Night ATT
905-Sender 916-MFCR
909-DCFT 917-MFCS
919 to 926-Modem
TK:
Trunk Number
TN:
Tenant Number
RSC:
Route Restriction Class
SFC:
Service Feature Class
STEP 4:
ARTD
- Routes must be assigned as either PB, DP, or DP/PB. CDN 2:ONSG, Type of Outgoing
Signal Selection (ONSG) is assigned to each route as data “1”, DP; data “2”, PB; or data “3”, DP/PB.