NEAX2400 IPX Feature Programming Manual
Page 582
NDA-24297, Issue 1
P-6
Pushbutton to Rotary Conversion
P-6 
Pushbutton to Rotary Conversion
General Description
This feature allows DTMF telephones to be used when DTMF signaling is not provided or are not available from
the Central Office and/or TIE Line.
Operating Procedure
Users dial the desired telephone numbers.
Service Conditions
1.
PUSHBUTTON TO ROTARY CONVERSION is software controlled on a per-trunk route basis.
2.
See UNIVERSAL SENDER
for reference.
3.
When the following combination of data settings are assigned, the PB station cannot originate a call:
ASDT
- TEC = 3 (DP/PB) station data for the calling station
ASPA
- SSC = OGC/OGCA
ARTD
- CDN1: OSGS = 2 (second dial tone)
CDN2: ONSG = 2 (PB, 60 msec. Interruption or CCIS No. 7)
Interactions
1.
Each 8RST circuit card contains four register and four sender circuits. Each register circuit can accept
either push-button or rotary dial pulses. The senders can outpulse push-button or dial pulse signals and are
used with the ATTENDANT CONSOLE [A-3], LEAST-COST ROUTING-3/6 DIGIT [L-5], SPEED
CALLING-SYSTEM, STATION, GROUP [S-3, 21, 23], OUTGOING TRUNK QUEUING [O-2], OFF-
HOOK QUEUING [O-7], and PUSHBUTTON-TO-ROTARY CONVERSION.
2.
Register circuits are located on the first four levels (0-3), and sender circuits are located on the last four
levels (4-7) of the 8RST circuit card.
3.
Each register may be assigned as either an outgoing or an incoming register. Incoming calls have priority
over outgoing calls. Thus, a register programmed as outgoing may serve as an incoming register when
none are available. However, an incoming register will never serve as an outgoing register.
Programming
STEP 1:
ASYD
- System Data 2, Index 2, Bit 0. Sender signal for station is DP/PB? 0/1: DP/PB. Always assign
as data “0”. Assign on a per-tenant basis. This Bit takes priority when ARTD, CDN 2:ONSG is
assigned as data “3”, DP/PB.
STEP 2:
ASDT
- Assign single-line stations a Telephone Equipment Class (TEC) of Push-button (PB) TEC = 2
or dial pulse/push-button (DP/PB), TEC = 3.
STEP 3:
ATRK
- Assign Originating Register Trunks (ORT) to the system in a quantity calculated from
expected traffic. Registers are located on levels 0-3 of any 8RST circuit card.
Also, senders must be assigned to the system in a quantity calculated from expected traffic. Senders
are located on levels 4-7 of any 8RST circuit card.
RT:
Route Number
Trunk Route Number
Intra-office Route Number (901-931)
901-ATT