8.2 Asset Data write 
This command is used in order to write Asset Data. 
1) The controller requests the monitor to write Asset data.  
Header 
Message 
Check code 
Delimiter 
SOH-'0'-Monitor ID-'0'-'A'-N-N 
STX-'C'-'0'-'0'-'E'-'0'-'0'- 
Data(0)-Data(1)---Data(N)-ETX 
BCC 
CR 
 
Header 
SOH (01h): Start Of Header 
'0' (30h): Reserved 
Monitor ID: Specify the Monitor ID in which you want to write data. 
Ex.) If Monitor ID is '1', specify 'A'. 
'0' (30h): Message sender is the controller. 
'A' (41h): Message type is "Command". 
N-N: Message length 
Note.) The maximum data length that can be written to the monitor at a time is 32bytes. 
Ex.) The byte data 20h is encoded as ASCII characters '2' and '0' (32h and 30h). 
 
Message 
STX (02h): Start of Message 
'C'-'0'-'0'-'E'  (43h, 30h, 30h, 45h): Asset Data writes command 
'0'-'0'(30h, 30h): Offset address from top of Asset data.  
00h : Write data from top of the Asset data area. 
Data(0) 
–- Data(N): Asset data. The data must be ASCII characters strings. 
ETX (03h): End of Message 
 
Check code 
BCC: Block Check Code 
      Refer to the section 4.5 
“Check code” for a BCC calculation. 
 
Delimiter 
CR (0Dh): End of packet 
 
2) The monitor replies a data for confirmation. 
Header 
Message 
Check code 
Delimiter 
SOH-'0'-'0'-Monitor ID-'B'-N-N 
STX-'0'-'0'-'C'-'0'-'0'-'E'-'0'-'0'- 
Data(0)-Data(1)---Data(N)-ETX 
BCC 
CR 
 
Header 
SOH (01h): Start Of Header 
'0' (30h): Reserved 
'0' (30h): Message receiver is the controller. 
Monitor ID: Indicate a replying Monitor ID. 
Ex.)  When this byte is set to 'A', the replying Monitor ID is '1'. 
'B' (42h): Message type is "Command reply". 
N-N: Message length 
Note.) The maximum data length that can be written to the monitor at a time is 32bytes. 
Ex.) The byte data 20h is encoded as ASCII characters '2' and '0' (34h and 30h). 
 
Message 
STX (02h): Start of Message 
'0'-'0': Result code. No error. 
'C'-'0'-'0'-'E'  (43h, 30h, 30h, 45h): Asset Data write command 
'0'-'0'(30h, 30h): Offset address from top of Asset data.  
00h : Write data into from top of the Asset data area. 
Data(0) 
–- Data(N): Asset data. The data must be ASCII characters strings. 
ETX (03h): End of Message 
 
Check code 
BCC: Block Check Code 
      Refer to the section 4.5 
“Check code” for a BCC calculation. 
 
Delimiter