12. Serial No. & Model Name Read 
12.1 Serial No. Read   
This command is used in order to read a serial number.
 
 
1) The controller requests the monitor to read a serial number. 
Header 
Message 
Check code 
Delimiter 
SOH-'0'-Monitor ID-'0'-'A'-'0'-'6' 
STX-'C'-'2'-'1'-'6'-ETX 
BCC 
CR 
 
Header 
SOH (01h): Start Of Header 
'0' (30h): Reserved 
Monitor ID: Specify the Monitor ID which you want to get serial number. 
Ex.) If Monitor ID is '1', specify 'A'. 
'0' (30h): Message sender is the controller. 
'A' (41h): Message type is "Command". 
'0'-'6'(30h, 36h): Message length 
      
Message 
STX (02h): Start of Message 
'C'-'2'-'1'-'6' (43h, 32h, 31h, 36h): Serial No. command 
ETX (03h): End of Message 
 
Check code 
BCC: Block Check Code 
      Refer to the section 4.5 
“Check code” for a BCC calculation.
 
 
Delimiter 
CR (0Dh): End of packet 
 
2) The monitor replies the serial No. data to the controller. 
Header 
Message 
Check code 
Delimiter 
SOH-'0'-'0'-Monitor ID-'B'-N-N 
STX-'C'-'3'-'1'-'6'- 
Data(0)-Data(1)---Data(n)-ETX 
BCC 
CR 
 
Header 
SOH (01h): Start Of Header 
'0' (30h): Reserved 
'0' (30h): Message receiver is the controller. 
Monitor ID: Indicate a replying Monitor ID. 
Ex.)  When this byte is set to 'A', the replying Monitor ID is '1'.  
'B' (42h): Message type is "Command reply". 
N-N: Message length 
Note.) The maximum data length that can be returned from the monitor at a time is 
32bytes. 
Ex.) The byte data 20h is encoded as ASCII characters '2' and '0' (32h and 30h). 
 
Message 
STX (02h): Start of Message 
'C'-'3'-'1'-'6' (41h, 33h, 31h, 36h): Serial No. reply command  
Data(0)-Data(1)----Data(n):Serial Number 
 
These data are encoded to ASCII characters strings. 
ETX (03h): End of Message 
 
Check code 
BCC: Block Check Code 
      Refer to the section 4.5 
“Check code” for a BCC calculation.
 
 
Delimiter 
CR (0Dh): End of packet