Juniper Networks 5000 SERIES Manuale Utente

Pagina di 116
Installing and Connecting the AC Power Supply
NetScreen-5000 Series 
17
I
NSTALLING
 
AND
 C
ONNECTING
 
THE
 AC P
OWER
 S
UPPLY
To install and connect the AC power supply to the NetScreen-5000 Series device:
1.
On the NetScreen-5200, slide the power supply into one of the power 
compartments in the back of the system.
On the NetScreen-5400, slide the power supply into one of the power 
compartments on the front of the system.
2.
Fasten the power supply to the system by tightening the corner screws into the 
eyelets on the sides of the power supply.
3.
If you want to install two power supplies in the NetScreen-5200 or three power 
supplies in the NetScreen-5400, repeat steps 1 and 2 for the remaining power 
supplies.
4.
Connect the female end of a standard power cord to the male connector on the 
back of each power supply.
5.
Connect each power cord to a standard 100-240-Volt power outlet.
6.
Turn the power switches on.
I
NSTALLING
 
AND
 W
IRING
 
A
 DC P
OWER
 S
UPPLY
To install and connect the DC power supply to the NetScreen-5000 Series device:
1.
On the NetScreen-5200, slide the power supply into one of the power 
compartments in the back of the system.
On the NetScreen-5400, slide the power supply into one of the power 
compartments on the front of the system.
2.
Fasten the power supply to the system by tightening the corner screws into the 
eyelets on the sides of the power supply.
3.
If you want to install two power supplies in the NetScreen-5200 or three power 
supplies in the NetScreen-5400, repeat steps 1 and 2 for the remaining power 
supplies.
Note: 
Whenever you deploy two or more power supplies to a NetScreen-5000 
Series device, connect each to a different power source. Each power supply is 
intended to receive power from separate feeds.
Note: 
If there are multiple power supplies in the NetScreen-5000 Series device 
and any of them are off, the Alarm LED on the management module glows red. 
This alarm indicates that maximum system stability requires all installed power 
supplies to be operational.