The NetScreen-5000 Series device allows you to configure the chassis alarm, an audible 
warning that sounds when a system failure or hazardous event occurs. To determine 
which failures and events trigger the chassis alarm:
1.
Configure the audible alarms by executing the following command:
set chassis audible-alarm string
where string can be any of the following keywords:
2.
After configuring the alarm, it is advisable to view alarm environment 
information by executing the following command:
get chassis
all
Enables all chassis alarms.
battery
Sets the chassis alarm to sound when a battery fails.
fan-failed
Sets the chassis alarm to sound when a fan fails.
power-failed
Sets the chassis alarm to sound when a power supply fails.
temperature
Sets the chassis alarm to sound when the temperature goes outside of 
the acceptable range.