Lightwave Communications SCS3230 Manuale Utente

Pagina di 97
ConsoleServer 3200 System  
 
Lightwave Communications 
Rev. A 
- 30 -  
www.lightwavecom.com 
Standard DB9 or DB25 installation: 
 
Materials: 
  SCS3230 device port 
  device with RS-232-C serial console port 
  RJ45-terminated Cat 5 cable (standard LAN cable) 
  Lightwave adapter for serial console port 
 
1. 
Attach the Lightwave adapter to the serial console port. 
 
2. 
Connect the Cat 5 cable to the adapter.  Connect the other end to the SCS3230 device 
port. 
 
3. 
Check that the device port and serial console port communications parameters match, 
and synchronize them if they do not match.   
 
Sun® Netra t1 installation: 
 
Materials: 
 
1. 
Connect a Cat 5 cable to the console port of the Netra.  Connect the other end to the 
end of the ConsoleServer/Netra adapter (P/N 200.0225) marked “to Netra”. 
 
2. 
Connect another Cat 5 cable between the adapter end marked “ConsoleServer” and the 
ConsoleServer device port. 
 
3. 
Check that the device port and serial console port communications parameters match, 
and synchronize them if they do not match.