Lightwave Communications SCS3230 Manuale Utente

Pagina di 97
ConsoleServer 3200 System  
 
Lightwave Communications 
Rev. A 
- 66 -  
www.lightwavecom.com 
If the card is a network card, it will immediately acquire the new network parameters and 
disconnect all telnet sessions to that card.  If a terminal card is in the slot, or if the slot is empty, 
the network parameter update is refused, but the network parameters for that slot will be saved 
to control card memory. 
 
When the 
NETWORK command is used with a card slot letter as a command qualifier, it will 
attempt to change the parameters only for that card slot.  In all other aspects, the command 
behaves the same as if the 
/ALL qualifier was used.  
 
If a bootp server is present on the same network as the SCS3230 network card and bootp is 
enabled on the network card, then the network card will use the IP address and subnet mask 
assigned by the bootp server rather than those assigned by the sys admin.  
 
Once a network card has been assigned an IP address either by a bootp server or by the sys 
admin, then the ConsoleServer may be accessed by telnet.  Connecting to the default telnet 
port reaches the user login; connecting to port 5000 reaches the sys admin login. 
 
7.8 
Modem Command 
 
The 
MODEM command allows manipulation of the modem card initialization string.  When the 
command is entered, the sys admin is prompted for the new initialization string.  Typing a new 
initialization string and pressing 
<ENTER> will create a new initialization string for the modem, 
while just pressing 
<ENTER> will accept the current value.  After pressing <ENTER>, the sys 
admin is asked to confirm the changes to send the string to the modem.  Typing 
YES and 
<ENTER> will send the initialization string immediately to the modem card, while typing NO and 
<ENTER> discards the entered initialization string and keeps the old string.  If the modem card is 
not currently installed, the settings are not sent, but are kept in control card memory.  The 
control card will send those settings in memory when a modem card is installed. 
 
 
sys admin>>MODEM 
Enter accepts present value 
Init string | > ATB2H0 
Save changes and update modem card?  Yes or No: No>yes 
Modem card not installed in slot A, init string saved 
 
Sys admin>MODEM /DEFAULT 
Current modem init string is: ATB2H0 
Set modem to factory default value of: ATH0S0=1 
(write out YES) Yes or No: No>yes 
Modem card not installed in slot A, init string saved 
 
sys admin>> 
 
 
The sys admin may also reset the initialization string to the default value by entering the 
command with the default qualifier in the form 
MODEM /DEFAULT.  When using the /DEFAULT 
qualifier, the current initialization string is displayed, along with the factory default string.  The 
sys admin is asked to confirm the use of the default modem string; typing 
YES and <ENTER> will 
send the default initialization string immediately to the modem card, while typing 
NO and 
<ENTER> keeps the old modem string.