Lightwave Communications SCS3230 Manuale Utente

Pagina di 97
A Lantronix Company  
 
SCS3230 System Administrator's Guide  
15.00.038
 
 - 69 - 
May 2002 
desires to list the software version for all cards, he should type 
VERSION /ALL at the 
command prompt.  This will list the versions of the boot and flash software for all cards, 
listed by card slot letter designation.  Each network card will display two sets of software 
versions: one set for the network portion of the card and one for the user terminal 
portion, while all other cards will only return one set of version information. 
 
7.9.4 
INFO Command 
 
sys admin>>INFO A 
Slot A1: Modem: No Active Call  Timeout = 1 mins. 
Current Modem State: in command mode 
Modem Init String: ATH0S0=1 
Modem error: none 
 
sys admin>INFO C 
Slot C2: 0 Active Telnet Sessions   Timeout = 1 mins. 
Ethernet Address: 00-30-31-00-00-4F 
IP=172.16.1.31  SM=255.255.255.0  GW=172.16.1.151 
2nd route: IP=255.255.255.255  SM=255.255.255.255  GW=255.255.255.255 
 
sys admin>>INFO D 
Slot D1: 
Port  9(A) DCE  38400,N,8,1 Flow=XON/XOFF RTS=0 DTR=1 
Port 10(B) DCE  38400,N,8,1 Flow=XON/XOFF RTS=0 DTR=1 
Port 11(c) DCE  38400,N,8,1 Flow=XON/XOFF RTS=0 DTR=1 
Port 12(D) DCE  38400,N,8,1 Flow=XON/XOFF RTS=0 DTR=1 
 
sys admin>> 
 
 
The 
INFO command allows the sys admin to list the properties of a card.  The switch cards are 
incapable of returning information, and any request to view information from the switch cards 
will be refused. 
 
The 
INFO command is used in the form INFO <slot letter>, where <slot letter> is 
the letter designation of the card slot in the SCS3230 chassis.  The modem card will always be 
in card slot A, while the network card may be in slots B, C, D, or E. 
 
The modem card will return the following information: 
 
  The slot letter and processor number (which will always be "A1") 
  The connection status of the modem 
  The current modem session timeout limit (see Section 6.9,Breaking User    Connections) 
  The current modem state, listed as either power-up mode or command mode 
  The modem initialization string sent at startup 
  Any miscellaneous modem error messages  
 
The network card will return the following information: 
 
  The slot letter and processor number (the number will always be “2”) 
  The amount of active telnet sessions 
  The telnet session timeout limit  
  Sys Admin sessions