INSTALLATION 
 
 
PAGE 12 
Optima 3 INS (Only)  – Install damper rod knob as ex-
plained on page 11. 
 
 
 
Adjustment Procedure: The damper knob should be 
positioned in the center of the oblong slot for the aver-
age installation (see illustration above). If more or less 
air is needed, then adjust in ¼" increments until opti-
mum combustion air flow is achieved (see Damper Ad-
justment Guidelines on page 26).  
 
 
Damper Locations 
See ‘Opening Side Panels’, page 33 for instructions on 
opening the side panels for models Optima 2 FS & Op-
tima 3 FS. See ‘Installing Surround Assembly’ for in-
structions on side surround panel access for model Op-
tima 3 INS. 
 
Optima 2 FS - The damper control handle is located on the 
right-hand side panel. 
 
Optima 3 FS - The damper control handle is located on the 
left-hand side panel. 
 
Optima 3 INS - The damper control handle is located on the 
left surround panel. 
 
 
Damper Adjustment 
It is very important to preset your damper prior to burn-
ing your pellet stove. 
 
 
Damper - Air Control Handle – Freestanding Units 
 
 
 
Adjustment Procedure:
 Loosen setscrew on set collar 
(see above picture), then adjust in ¼" increments until 
optimum combustion air flow is achieved. For less air 
push in and for more air pull out. After adjustment, posi-
tion set collar against side panel and tighten setscrew. 
 
 
Damper is factory set to a gap as 
specified below. Follow Damper 
Adjustment Guidelines on page 26.
To adjust, use a 
3/32" allen wrench 
to loosen set collar. 
1 5/8" – Optima 3 FS 
1 1/2" – Optima 2 FS 
Damper 
Knob 
Left  
Surround 
Panel 
More Air 
 
Less Air
 
For less air, slide 
damper knob to the 
right (or) for more air, 
slide knob to the left.